AHT Series

AHT615-P-RIS – mV Input Trip Amplifier

The AHT615-P-RIS is our millivolt input trip amplifier unit suitable for SIL 1, 2 & 3 applications Input is any signal within a span of 4 to 400mV Trip output...

The AHT615-P-RIS is our millivolt input trip amplifier unit suitable for SIL 1, 2 & 3 applications Input is any signal within a span of 4 to 400mV Trip output…

AHP991-RIS-8006

AHP991-RIS-8006 – High Current DC Output Power Supply

...that it is a direct plug-in replacement for existing RIS 19” racks. Supply voltage 115V or 230Vac (±10%) Output 24Vdc @ up to 2.5A Consumption 75VA (@ 2.5A output) Environmental...

…that it is a direct plug-in replacement for existing RIS 19” racks. Supply voltage 115V or 230Vac (±10%) Output 24Vdc @ up to 2.5A Consumption 75VA (@ 2.5A output) Environmental…

ATA120 Resistance Temperature Sensor Input Trip Amplifier

The ATA120 is our resistance temperature sensor trip amplifier suitable for SIL 1, 2 & 3 applications Input Single channel Double channel Single Trip Double Trip Single Trip Double Trip...

The ATA120 is our resistance temperature sensor trip amplifier suitable for SIL 1, 2 & 3 applications Input Single channel Double channel Single Trip Double Trip Single Trip Double Trip…

ATA110 Thermocouple Temperature And Millivolt Input Trip Amplifier

The ATA110 is our thermocouple and millivolt trip amplifier suitable for SIL 1, 2 & 3 applications Input Single channel Double channel Single Trip Double Trip Single Trip Double Trip...

The ATA110 is our thermocouple and millivolt trip amplifier suitable for SIL 1, 2 & 3 applications Input Single channel Double channel Single Trip Double Trip Single Trip Double Trip…

AHT Series

AHM710 – Millivolt Input Trip Transmitter

...from thermocouple Type S, R, B, J, K, T, E, N and other special types also available on request. Output DC current or voltage specified in ranges seen on datasheet...

…from thermocouple Type S, R, B, J, K, T, E, N and other special types also available on request. Output DC current or voltage specified in ranges seen on datasheet…

ASC-X Series

ASC-X Series – DC Current Input Split Core Transducer (200-2000Amp Ranges)

...ranges from 200A DC up to 2000A DC, with Ø40.5mm through hole. Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C +100°C Operating Ambient: -25°C to +85°C Relative Humidity 5%...

…ranges from 200A DC up to 2000A DC, with Ø40.5mm through hole. Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C +100°C Operating Ambient: -25°C to +85°C Relative Humidity 5%…

ASC330

ASC330 – DC Current Input Transducer

Our ASC330 is a DC Current Input Transducer that allows for non-intrusive monitoring and can either be set for single or bidirectional sensing. It is perfect in use for Motor...

Our ASC330 is a DC Current Input Transducer that allows for non-intrusive monitoring and can either be set for single or bidirectional sensing. It is perfect in use for Motor…

ADT181KXT

ADT181KXT – Pulse Count Input Trip Amplifier

Our ADT181KXT is a Pulse Count Input Trip Amplifier suitable for SIL1, SIL2 and SIL3 (IEC61508-2) rated safety loop applications with a supply voltage of 24Vdc (Other ranges available on...

Our ADT181KXT is a Pulse Count Input Trip Amplifier suitable for SIL1, SIL2 and SIL3 (IEC61508-2) rated safety loop applications with a supply voltage of 24Vdc (Other ranges available on…

Current Sensor

ACT10 – Non-Intrusive AC Current Input Sensor

Our ACT-10 is an AC Split-Core current input sensor with a Self-Locking mechanism and provides easy installation.   It is suitable for non-intrusive monitoring, surface mounted current monitoring & AC current...

Our ACT-10 is an AC Split-Core current input sensor with a Self-Locking mechanism and provides easy installation.   It is suitable for non-intrusive monitoring, surface mounted current monitoring & AC current…