AHM Series – All Input & Output Transmitters / Trip Transmitter ...Output Single Trip Dual Trip HP Wide >1% fixed deadband Variable deadband Supply 24Vdc 155/ 230Vac Linearised Output Upscale on open circuit Downscale on open circuit RFI Protection LED or... …Output Single Trip Dual Trip HP Wide >1% fixed deadband Variable deadband Supply 24Vdc 155/ 230Vac Linearised Output Upscale on open circuit Downscale on open circuit RFI Protection LED or…
ADC355 – Pulse Input Repeater / Isolator The ADC355 is our pulse signal input repeater / isolator output suitable for SIL 1, 2 & 3 applications Input can be specified as volt free contacts Output repeat can... The ADC355 is our pulse signal input repeater / isolator output suitable for SIL 1, 2 & 3 applications Input can be specified as volt free contacts Output repeat can…
ASC005 – 5A Compact DC Current Input Transducer Our ASC005 Compact DC Current Input Transducer – with a split core and condensed size that allows for non-intrusive monitoring and is loop powered in order to reduce wiring. It’s... Our ASC005 Compact DC Current Input Transducer – with a split core and condensed size that allows for non-intrusive monitoring and is loop powered in order to reduce wiring. It’s…
ADC371 – Rate of Change Input Transmitter / Isolator The ADC371 is our rate of change signal input signal transmitter suitable for SIL 1, 2 & 3 applications Input is any DC current or voltage can be specified in... The ADC371 is our rate of change signal input signal transmitter suitable for SIL 1, 2 & 3 applications Input is any DC current or voltage can be specified in…
ADW451 – AC Current Two-Wire Input Transmitter ...Supply is nominal 24Vdc (can vary from 12 to 36V dc) Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C Relative Humidity 5%... …Supply is nominal 24Vdc (can vary from 12 to 36V dc) Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C Relative Humidity 5%…
ADW511 – Millivolt Two-Wire Input Transmitter ...cold junction compensation fitted as standard Supply is nominal 24Vdc (can vary from 12 to 36V dc) Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient:... …cold junction compensation fitted as standard Supply is nominal 24Vdc (can vary from 12 to 36V dc) Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient:…
ADW521 – RTD Two-Wire Input Temperature Transmitter ...may be specified Supply is nominal 24Vdc (can vary from 12 to 36V dc) Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C... …may be specified Supply is nominal 24Vdc (can vary from 12 to 36V dc) Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C…
AEC122 – AC/DC RTD Input Temperature Trip Amplifier ...2 independent relay outputs, each trip relay provides a changeover contact output, rated at 250V AC 2A, 120V AC 1A (24Vdc 2A). Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature:... …2 independent relay outputs, each trip relay provides a changeover contact output, rated at 250V AC 2A, 120V AC 1A (24Vdc 2A). Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature:…
AEC222 – AC/DC RTD Input Temperature Signal Trip-Transmitter/Isolator The AEC222 is our AC/DC RTD Temperature Signal Trip-Transmitter/Isolator with suitable for 2/3-wire PT100 RTD input Input from 2 or 3 wire RTD sensor (PT100) with a span greater than... The AEC222 is our AC/DC RTD Temperature Signal Trip-Transmitter/Isolator with suitable for 2/3-wire PT100 RTD input Input from 2 or 3 wire RTD sensor (PT100) with a span greater than…
ADT121KX-4W-RIS-ET7274 – RTD Input Temperature (4-wire) Output Trip Amplifier ...Response time: <400mS Isolation: 500Vdc Input/Contacts/Supply/Earth Mounting/Dimensions Enclosure: 50w x 75h x 182d mm Din Rail (TS35) mounting as standard View Datasheet Request A Quote Name Email Message Request Quote... …Response time: <400mS Isolation: 500Vdc Input/Contacts/Supply/Earth Mounting/Dimensions Enclosure: 50w x 75h x 182d mm Din Rail (TS35) mounting as standard View Datasheet Request A Quote Name Email Message Request Quote…