ADT133

ADM232MPX – Surface Mounting Pressure Input Trip Transmitter / Isolator

...to 0-1500bar. Any standard process current or voltage signal, Current source up to 20mA. Drive voltage 11Vdc Voltage source up to 10V. Max current 20mA Environmental Condition Performance Mounting /...

…to 0-1500bar. Any standard process current or voltage signal, Current source up to 20mA. Drive voltage 11Vdc Voltage source up to 10V. Max current 20mA Environmental Condition Performance Mounting /…

ADM240DI

ADM240DI – Potentiometer Input Signal Transmitter with Display

The ADM240DI is a Potentiometer Transmitter with Display suitable for any potentiometer / resistance input, process outputs and SIL1, SIL2 & SIL3 rated safety loop applications. This product has the...

The ADM240DI is a Potentiometer Transmitter with Display suitable for any potentiometer / resistance input, process outputs and SIL1, SIL2 & SIL3 rated safety loop applications. This product has the…

ADT133

ADM250 – AC Current/Voltage Input Signal Transmitter / Isolator

...ac Any standard process current or voltage in the range of; Current source up to 22mA max, with drive voltage 24Vdc Environmental Condition Performance Mounting / Dimensions Environmental Condition Storing...

…ac Any standard process current or voltage in the range of; Current source up to 22mA max, with drive voltage 24Vdc Environmental Condition Performance Mounting / Dimensions Environmental Condition Storing…

ADT133

ADM271 – Strain Gauge Input Signal Transmitter / Splitter/ Isolator

...applications, as 1oo1 architecture (HFT:0) Input is any mV signal range with a minimum span of 4mV (Excitation; 10Vdc at up to 30mA as standard, 5V or 24Vdc available) Provides...

…applications, as 1oo1 architecture (HFT:0) Input is any mV signal range with a minimum span of 4mV (Excitation; 10Vdc at up to 30mA as standard, 5V or 24Vdc available) Provides…

ADT133

ADM281 – Frequency Input Transmitter – Dual Output

The ADM281 is our dual output frequency input signal transmitter suitable for SIL 1, 2 & 3 units. Supply voltages 115Vac ±20%; 240Vac ±20% 24Vdc ±2.5V; 48Vdc ±5V Input can...

The ADM281 is our dual output frequency input signal transmitter suitable for SIL 1, 2 & 3 units. Supply voltages 115Vac ±20%; 240Vac ±20% 24Vdc ±2.5V; 48Vdc ±5V Input can…

ADT171

ADM282 – Pulse/Frequency Input Signal Trip Transmitter

...Supply voltages: 115Vac ±20%; 240Vac ±20% 24Vdc ±2.5V; 48Vdc ±5V Input is any regular pulse or repetetive waveform including Namur, Sine, Square or Sawtooth. Input level may be anywhere between...

…Supply voltages: 115Vac ±20%; 240Vac ±20% 24Vdc ±2.5V; 48Vdc ±5V Input is any regular pulse or repetetive waveform including Namur, Sine, Square or Sawtooth. Input level may be anywhere between…

ADT135

ADM286 – Frequency Input Trip Transmitter / Isolator

The ADM286 is our frequency input trip transmitter / signal isolator suitable for SIL 1, 2 & 3 units. Supply voltages 115Vac ±20% 240Vac ±20% 24Vdc ±2.5V 48Vdc ±5V Input...

The ADM286 is our frequency input trip transmitter / signal isolator suitable for SIL 1, 2 & 3 units. Supply voltages 115Vac ±20% 240Vac ±20% 24Vdc ±2.5V 48Vdc ±5V Input…

ASC332

ASC332 – DC Input Current Transducer with Trip

Our ASC332 is a compact size DC/Process Current Input Trip Transducer that is loop powered in order to reduce wiring and can either be set for single or bidirectional sensing....

Our ASC332 is a compact size DC/Process Current Input Trip Transducer that is loop powered in order to reduce wiring and can either be set for single or bidirectional sensing….

ADT133

ADP451SP – Self Powered AC Current Input Transducer

Our range of AC current transducers are suitable for various combinations of AC Current inputs & DC Voltage/Current outputs and are also suitable for use in SIL1, SIL2 and SIL3...

Our range of AC current transducers are suitable for various combinations of AC Current inputs & DC Voltage/Current outputs and are also suitable for use in SIL1, SIL2 and SIL3…

APM489

APM489 – AC Input Moving Iron Ammeters/Voltmeter

Our AC Moving Iron Ammeter / Voltmeter can handle various custom of input ranges both AC and DC with display ranges customised to your needs. Our short-scale (90° sweep) &...