AEC232 – 4-20mA Process Input Signal Isolator Output with Trip

Our AEC232 4-20mA Signal Isolator W/ Trip Amplifier – suitable for combinations of process V/I (DC) input and output signals with a trip set point. The AEC232 boasts innovatively integrated...

Our AEC232 4-20mA Signal Isolator W/ Trip Amplifier – suitable for combinations of process V/I (DC) input and output signals with a trip set point. The AEC232 boasts innovatively integrated…

ADT132DI – Process Input Dual Output Trip Amplifier With LED Display

...surface mounting enclosure. Display indicating the trip input and trip set points. Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C Relative Humidity:...

…surface mounting enclosure. Display indicating the trip input and trip set points. Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C Relative Humidity:…

ADG230

ADG230 – 4-20mA Process Input Ultra Compact Signal Isolator

Our ADG230 Ultra Compact Signal Isolator – innovatively integrated isolation and 1:1 conversion of standard current signals. Boasting a ultra-compact design within a 10mm wide clip on terminal style enclosure,...

Our ADG230 Ultra Compact Signal Isolator – innovatively integrated isolation and 1:1 conversion of standard current signals. Boasting a ultra-compact design within a 10mm wide clip on terminal style enclosure,…

ADT135

ADT112 – Thermocouple Dual Trip Amplifier

...Bi-colour red/green LED, RFI protection (IEC61000-4-3) and more. The instrumentation is manufactured within our high impact strength, polycarbonate din rail & surface mounting enclosure. Input is any mV signal developed...

…Bi-colour red/green LED, RFI protection (IEC61000-4-3) and more. The instrumentation is manufactured within our high impact strength, polycarbonate din rail & surface mounting enclosure. Input is any mV signal developed…

AEC230X

AEC230X – Contact Closure Output Universal Input Signal Generator

...+55°C Relative Humidity: 5% to 95% RH Mounting/Dimensions Enclosure: 22.5w x 75h x 105d mm Mounting: Din Rail (TS35) AEC230X Signal Booster/Isolator Datasheet AEC230X Contact Closure Current Generator Datasheet Request...

…+55°C Relative Humidity: 5% to 95% RH Mounting/Dimensions Enclosure: 22.5w x 75h x 105d mm Mounting: Din Rail (TS35) AEC230X Signal Booster/Isolator Datasheet AEC230X Contact Closure Current Generator Datasheet Request…

ADP901-2 Dual Channel Loop Power Supply Unit

...to 95% RH (Non-Condensing) Performance Isolation: 1000VRMS* Output/Output/Supply/Earth *(500Vdc if RFI protection option ‘K’ is specified) Supply Consumption: <3VA Mounting/Dimensions Enclosure: 50w x 75h x 110d mm (‘K’ option =...

…to 95% RH (Non-Condensing) Performance Isolation: 1000VRMS* Output/Output/Supply/Earth *(500Vdc if RFI protection option ‘K’ is specified) Supply Consumption: <3VA Mounting/Dimensions Enclosure: 50w x 75h x 110d mm (‘K’ option =…

ADT151

ADT115 – mV Input Trip Amplifier with Single set point

...surface mounting enclosure. Input is any mV signal upto 400mV with a minumum of 4mV span as std Trip output is a set of changeover contacts (D.P.C.O) rated at 250VAC,...

…surface mounting enclosure. Input is any mV signal upto 400mV with a minumum of 4mV span as std Trip output is a set of changeover contacts (D.P.C.O) rated at 250VAC,…

ADT133

ADM239X-RSP Process Signal Deviation Controller / Isolator

...Mounting/Dimensions Enclosure: 50w x 75h x 110d mm Mounting: Din Rail (TS35) or Surface by corner fixing holes View Datasheet Request A Quote Company Location Name Email Telephone Message Request...

…Mounting/Dimensions Enclosure: 50w x 75h x 110d mm Mounting: Din Rail (TS35) or Surface by corner fixing holes View Datasheet Request A Quote Company Location Name Email Telephone Message Request…

ADT135

ADT122 – RTD Input Trip Amplifier

...& surface mounting enclosure. Input is any 2 or 3 Wire PT100 resistance temperature sensor. Trip output is a set of double pole changeover contacts (DPCO), rated at 250VAC, 3A,...

…& surface mounting enclosure. Input is any 2 or 3 Wire PT100 resistance temperature sensor. Trip output is a set of double pole changeover contacts (DPCO), rated at 250VAC, 3A,…

ADM230X-4

ADT128 – RTD Input Quad Output Trip Amplifier

...Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C Relative Humidity 5% to 95% RH Performance Trip settability: ±1% Trip repeatability: ±0.1% Response time: <400mS Mounting/Dimensions Enclosure:...

…Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C Relative Humidity 5% to 95% RH Performance Trip settability: ±1% Trip repeatability: ±0.1% Response time: <400mS Mounting/Dimensions Enclosure:…