ADT171

ADC/ADP/AGS Series – Arithmetic units & PSU

SKU: ADC/ADP/AGS Series The ADC Series Arithmetic units are process signal input instruments for Summation, Averaging, Deviation, Differential or Subtraction, high or low level selection, or any other similar applications...

SKU: ADC/ADP/AGS Series The ADC Series Arithmetic units are process signal input instruments for Summation, Averaging, Deviation, Differential or Subtraction, high or low level selection, or any other similar applications…

ADT133

ADM221X – Dual Output RTD/Temperature Input Signal Splitter

...enclosure and is suitable for use in SIL1, SIL2 & SIL3 rated safety loop applications (IEC61508-2). Furthermore the AMELEC standard 10 year warranty applies to this instrument. Environmental Condition Performance...

enclosure and is suitable for use in SIL1, SIL2 & SIL3 rated safety loop applications (IEC61508-2). Furthermore the AMELEC standard 10 year warranty applies to this instrument. Environmental Condition Performance…

AEC231

AEC211 – Thermocouple Input Temperature Transmitter

...to +70°C Operating Ambient: 0°C to +55°C Relative Humidity: 5% to 95% RH Performance Isolation: 1000V RMS Input/Output/Supply Mounting/Dimensions Enclosure: 22.5w x 75h x 105d mm Mounting: Din Rail (TS35)...

…to +70°C Operating Ambient: 0°C to +55°C Relative Humidity: 5% to 95% RH Performance Isolation: 1000V RMS Input/Output/Supply Mounting/Dimensions Enclosure: 22.5w x 75h x 105d mm Mounting: Din Rail (TS35)…

AEC132

AEC122 – AC/DC RTD Input Temperature Trip Amplifier

...-20°C to +70°C Operating Ambient: 0°C to +55°C Relative Humidity: 5% to 95% RH Performance Isolation: 1000V RMS Input/Output/Supply Mounting/Dimensions Enclosure: 22.5w x 75h x 105d mm Mounting: Din Rail...

…-20°C to +70°C Operating Ambient: 0°C to +55°C Relative Humidity: 5% to 95% RH Performance Isolation: 1000V RMS Input/Output/Supply Mounting/Dimensions Enclosure: 22.5w x 75h x 105d mm Mounting: Din Rail…

AEC231

AEC221 – AC/DC RTD Input Temperature Signal Transmitter/Splitter

...Relative Humidity: 5% to 95% RH (Non-Condensing) Performance Accuracy/Linearity: <±0.1% span Response time: <300mS (0-100% input step change) Supply consumption: <3VA Mounting/Dimensions Enclosure: 22.5w x 75h x 105d mm Mounting:...

…Relative Humidity: 5% to 95% RH (Non-Condensing) Performance Accuracy/Linearity: <±0.1% span Response time: <300mS (0-100% input step change) Supply consumption: <3VA Mounting/Dimensions Enclosure: 22.5w x 75h x 105d mm Mounting:…

AEC222 – AC/DC RTD Input Temperature Signal Trip-Transmitter/Isolator

...Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -20°C to +70°C Operating Ambient: 0°C to +55°C Relative Humidity: 5% to 95% RH Performance Isolation: 1000Vdc Input/Output/Contracts/Supply Mounting/Dimensions Enclosure: 22.5w x 75h...

…Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -20°C to +70°C Operating Ambient: 0°C to +55°C Relative Humidity: 5% to 95% RH Performance Isolation: 1000Vdc Input/Output/Contracts/Supply Mounting/Dimensions Enclosure: 22.5w x 75h…

ADT133

ADW231 – Dual Output Process Input Loop Powered Transmitter

...±1% Trip repeatability: ±0.1% Mounting/Dimensions Enclosure: 50w x 75h x 110d mm Din Rail (TS35) or Surface by corner fixing holes View Datasheet Request A Quote Company Location Name Email...

…±1% Trip repeatability: ±0.1% Mounting/Dimensions Enclosure: 50w x 75h x 110d mm Din Rail (TS35) or Surface by corner fixing holes View Datasheet Request A Quote Company Location Name Email…

ADM240DI

ADT121KX-4W-RIS-ET7274 – RTD Input Temperature (4-wire) Output Trip Amplifier

...Response time: <400mS Isolation: 500Vdc Input/Contacts/Supply/Earth Mounting/Dimensions Enclosure: 50w x 75h x 182d mm Din Rail (TS35) mounting as standard View Datasheet Request A Quote Name Email Message Request Quote...

…Response time: <400mS Isolation: 500Vdc Input/Contacts/Supply/Earth Mounting/Dimensions Enclosure: 50w x 75h x 182d mm Din Rail (TS35) mounting as standard View Datasheet Request A Quote Name Email Message Request Quote…

ADT135

ADT133X – Auto Input Switch

...set by the trip 1, if input 1 falls below this level input 1 is switched off and input 2 is switched to the output Mounting/Dimensions Mounting/Dimensions Enclosure: 50w x...

…set by the trip 1, if input 1 falls below this level input 1 is switched off and input 2 is switched to the output Mounting/Dimensions Mounting/Dimensions Enclosure: 50w x…

ADM230X-4

ADT138 – Process I/V Input Quad Output Trip Amplifier

...Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C Relative Humidity: 5% to 95% RH Performance Trip settability: ±1% Trip repeatability: ±0.1% Response time: <100mS Mounting/Dimensions Enclosure:...

…Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C Relative Humidity: 5% to 95% RH Performance Trip settability: ±1% Trip repeatability: ±0.1% Response time: <100mS Mounting/Dimensions Enclosure:…