ADT121DI – RTD Input Trip Amplifier with Single Set Point and Display

Our ADT121DI RTD input Trip Amplifier is suitable SIL1, SIL2 & SIL3 rated safety loop applications (IEC61508-2). The instrumentation is manufactured within our high impact strength, polycarbonate din rail &...

Our ADT121DI RTD input Trip Amplifier is suitable SIL1, SIL2 & SIL3 rated safety loop applications (IEC61508-2). The instrumentation is manufactured within our high impact strength, polycarbonate din rail &…

AST122N – RTD Input Temperature Trip Amplifier With Two Outputs

The AST122N is our Thermocouple Temperature Signal trip amplifier with two trip output set points suitable for SIL 1, 2 & 3 applications Input is any 2, 3 or 4...

The AST122N is our Thermocouple Temperature Signal trip amplifier with two trip output set points suitable for SIL 1, 2 & 3 applications Input is any 2, 3 or 4…

ADT151

ADT111 – Thermocouple Trip Amplifier with Single set point

Our ADT111 Thermocouple Input Single Set Point Trip Amplifier is suitable SIL1, SIL2 & SIL3 rated safety loop applications (IEC61508-2). We can provide several add-on options such as upscale on...

Our ADT111 Thermocouple Input Single Set Point Trip Amplifier is suitable SIL1, SIL2 & SIL3 rated safety loop applications (IEC61508-2). We can provide several add-on options such as upscale on…

Digital Panel Meter

APM489-4-RL Digital Countdown Timer with Trip Relay contact

...orders It is is a high stability & low cost panel meter with a 24Vdc standard supply. (48Vdc option available on request). View Datasheet Request A Quote Company Location Name...

…orders It is is a high stability & low cost panel meter with a 24Vdc standard supply. (48Vdc option available on request). View Datasheet Request A Quote Company Location Name…

ADT111DI – Thermocouple Trip Amplifier with Single set point And Display

Our ADT111DI Thermocouple Input Single Set Point Trip Amplifier with Display is suitable SIL1, SIL2 & SIL3 rated safety loop applications (IEC61508-2). We can provide several add-on options such as...

Our ADT111DI Thermocouple Input Single Set Point Trip Amplifier with Display is suitable SIL1, SIL2 & SIL3 rated safety loop applications (IEC61508-2). We can provide several add-on options such as…

APM489-6

APM489-6-BCD – Six Decade BCD Display

...is isolated from the power supply and has a standard 24Vdc supply (48Vdc supply option available on request) Display is 6 x 0.5” red LED digit high brightness display 000000...

…is isolated from the power supply and has a standard 24Vdc supply (48Vdc supply option available on request) Display is 6 x 0.5” red LED digit high brightness display 000000…

ASM230

AST111 – Thermocouple Input Trip Amplifier

...N, R, S, T) with minimum 4mV span Trip output is a double pole changeover contacts, rated at 250VAC, 2A, 100VA resistive Performance Mounting/Dimensions Performance Isolation: 1000Vdc RMS Input/Contacts-Contacts/Supply Mounting/Dimensions...

…N, R, S, T) with minimum 4mV span Trip output is a double pole changeover contacts, rated at 250VAC, 2A, 100VA resistive Performance Mounting/Dimensions Performance Isolation: 1000Vdc RMS Input/Contacts-Contacts/Supply Mounting/Dimensions…

Digital Panel Meter

APM489-4 – 4 Digit Contact Closure Start Input Countdown Timer

...low cost panel meter with a 24Vdc standard supply. (48Vdc option available on request) It also features a remote contact start and reset facility. View Datasheet Request A Quote Company...

…low cost panel meter with a 24Vdc standard supply. (48Vdc option available on request) It also features a remote contact start and reset facility. View Datasheet Request A Quote Company…

APM489-6

APM489-6 – 6 Digit Volt Free Contact/DC Pulse Input Counter Meter

...Pulse input (other input types available on request) and has a standard 115/230Vac supply (24Vdc supply option available on request) Local reset facility through Front Fascia (Reset by remote contact...

…Pulse input (other input types available on request) and has a standard 115/230Vac supply (24Vdc supply option available on request) Local reset facility through Front Fascia (Reset by remote contact…