ACT10 – Non-Intrusive AC Current Input Sensor Our ACT-10 is an AC Split-Core current input sensor with a Self-Locking mechanism and provides easy installation. It is suitable for non-intrusive monitoring, surface mounted current monitoring & AC current... Our ACT-10 is an AC Split-Core current input sensor with a Self-Locking mechanism and provides easy installation. It is suitable for non-intrusive monitoring, surface mounted current monitoring & AC current…
ADP416 – 3-Phase 4-Wire Unbalanced Watt/Power Transducer The ADP416 3-Phase 4-Wire Unbalanced Watt/Power Transducer is suitable for combinations of process inputs. Standard input current 0-1 or 0-5Amps, Direct or via CT’s. Standard input voltage 63V, 115V, 230V... The ADP416 3-Phase 4-Wire Unbalanced Watt/Power Transducer is suitable for combinations of process inputs. Standard input current 0-1 or 0-5Amps, Direct or via CT’s. Standard input voltage 63V, 115V, 230V…
ADR131X-3 – Three Way Output Interface Relay ...to 110V DC applied via the Relay Contact Outputs are 3 repeat C.O contacts rated 8A 250Vac as standard, however output can be specified. Environmental Condition Mounting/Dimensions Environmental Condition Storage... …to 110V DC applied via the Relay Contact Outputs are 3 repeat C.O contacts rated 8A 250Vac as standard, however output can be specified. Environmental Condition Mounting/Dimensions Environmental Condition Storage…
AGS1126X-EP – Heading Rate of Change Sensor The AGS1126X-EP is an externally powered Heading Rate of Change Sensor suitable for applications requiring precise rate of change of heading measurements along a single axis under harsh circumstances and... The AGS1126X-EP is an externally powered Heading Rate of Change Sensor suitable for applications requiring precise rate of change of heading measurements along a single axis under harsh circumstances and…
ADR131X-5-DC – Five Way Output Interface Relay ...DC applied Relay Contact 5 X Repeat C.O Contacts, rated 8A 250Vac as standard. Maybe be specified as ether all N.O or N.C contacts, or as a combination of both... …DC applied Relay Contact 5 X Repeat C.O Contacts, rated 8A 250Vac as standard. Maybe be specified as ether all N.O or N.C contacts, or as a combination of both…
AGS1135 – Water Usage Monitor / Controller ...from flow meter Output is 240Vac (16A max) Mains LIVE normally active and de-activated on Trip. Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C... …from flow meter Output is 240Vac (16A max) Mains LIVE normally active and de-activated on Trip. Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C…
ASM210 – Thermocouple Input Temperature Transmitter/Isolator ...-15°C to +55°C Relative Humidity: 5% to 95% RH (Non-Condensing) Performance Isolation: 1000V RMS Input/Output/Supply Linearity/Accuracy: <±0.1 mV Span Response time: <200mS Input Over range: <300% Mounting/Dimensions Enclosure: 22.5w x... …-15°C to +55°C Relative Humidity: 5% to 95% RH (Non-Condensing) Performance Isolation: 1000V RMS Input/Output/Supply Linearity/Accuracy: <±0.1 mV Span Response time: <200mS Input Over range: <300% Mounting/Dimensions Enclosure: 22.5w x…
AGS1126 – Heading Rate of Change Sensor The AGS1126 is a Heading Rate of Change Sensor suitable for applications requiring precise rate of change of heading measurements along a single axus under harsh circumstances and returning to... The AGS1126 is a Heading Rate of Change Sensor suitable for applications requiring precise rate of change of heading measurements along a single axus under harsh circumstances and returning to…
ACC315 – Process Signal Input Multiplier / Divider Unit The ACC315 is our Process Signal Input Multiplier / Divider Unit for SIL 1, 2 & 3 applications. Multiplication and divider unit can be used for multiple applications requiring a... The ACC315 is our Process Signal Input Multiplier / Divider Unit for SIL 1, 2 & 3 applications. Multiplication and divider unit can be used for multiple applications requiring a…