ADT133

ADC355 – Pulse Input Repeater / Isolator

The ADC355 is our pulse signal input repeater / isolator output suitable for SIL 1, 2 & 3 applications Input can be specified as volt free contacts Output repeat can...

The ADC355 is our pulse signal input repeater / isolator output suitable for SIL 1, 2 & 3 applications Input can be specified as volt free contacts Output repeat can…

ASC005

ASC005 – 5A Compact DC Current Input Transducer

Our ASC005 Compact DC Current Input Transducer – with a split core and condensed size that allows for non-intrusive monitoring and is loop powered in order to reduce wiring. It’s...

Our ASC005 Compact DC Current Input Transducer – with a split core and condensed size that allows for non-intrusive monitoring and is loop powered in order to reduce wiring. It’s…

ADT133

ADC371 – Rate of Change Input Transmitter / Isolator

The ADC371 is our rate of change signal input signal transmitter suitable for SIL 1, 2 & 3 applications Input is any DC current or voltage can be specified in...

The ADC371 is our rate of change signal input signal transmitter suitable for SIL 1, 2 & 3 applications Input is any DC current or voltage can be specified in…

ADT133

ADC374 – Ramp Output Generator Unit

The ADC374 is our ramp generator unit controlable via volt free contact closure inputs suitable for SIL 1, 2 & 3 applications Inputs are a free contact closure/opening to either...

The ADC374 is our ramp generator unit controlable via volt free contact closure inputs suitable for SIL 1, 2 & 3 applications Inputs are a free contact closure/opening to either…

ADT133

ADC375 – Ramp Output Generator Unit

The ADC375 is our ramp generator with controlable timings via two input terminals unit for SIL 1, 2 & 3 applications Inputs are volt free contact closure/opening to either raise...

The ADC375 is our ramp generator with controlable timings via two input terminals unit for SIL 1, 2 & 3 applications Inputs are volt free contact closure/opening to either raise…

ADT133

ADW451 – AC Current Two-Wire Input Transmitter

The ADW451 is our AC current input two wire supply/output transmitter suitable for SIL 1, 2 & 3 applications Input is any standard 0 to 1 Amp or 0 to...

The ADW451 is our AC current input two wire supply/output transmitter suitable for SIL 1, 2 & 3 applications Input is any standard 0 to 1 Amp or 0 to…

AEC231

AEC241 – Dual Output Resistance Input Transmitter

The AEC241 is a Dual Output Potentiometer / Resistance Signal Transmitter calibrated and manufactured within our high impact polycarbonate enclosure and is suitable for combinations of Potentiometer Input & process Voltage...

The AEC241 is a Dual Output Potentiometer / Resistance Signal Transmitter calibrated and manufactured within our high impact polycarbonate enclosure and is suitable for combinations of Potentiometer Input & process Voltage…

ADT133

ADW511 – Millivolt Two-Wire Input Transmitter

The ADW511 is our Millivolt Input two wire supply/output transmitter suitable for SIL 1, 2 & 3 applications Input is any signal developed from a thermocouple greater than 4mV. Automatic...

The ADW511 is our Millivolt Input two wire supply/output transmitter suitable for SIL 1, 2 & 3 applications Input is any signal developed from a thermocouple greater than 4mV. Automatic…

ADT133

ADW521 – RTD Two-Wire Input Temperature Transmitter

The ADW521 is our Two wire supply/output temperature signal input transmitter suitable for SIL 1, 2 & 3 applications Input is any temperature range from 2 or 3 Wire RTD...

The ADW521 is our Two wire supply/output temperature signal input transmitter suitable for SIL 1, 2 & 3 applications Input is any temperature range from 2 or 3 Wire RTD…

ADT133

ADW531 – Process Input Two Wire Transmitter/Isolator

The ADW531 is our Process input two wire supply/output transmitter suitable for SIL 1, 2 & 3 applications Input is an process current or voltage drive that can be terminated...

The ADW531 is our Process input two wire supply/output transmitter suitable for SIL 1, 2 & 3 applications Input is an process current or voltage drive that can be terminated…