AGS1126X-EP – Heading Rate of Change Sensor ...(SIS) loop monitoring applications, as 1oo1 architecture (HFT:0) This unit is suitable for areas such as aviation, marine, automotive & transportation systems; vehicles, aircraft, ships & vessels, as well as... …(SIS) loop monitoring applications, as 1oo1 architecture (HFT:0) This unit is suitable for areas such as aviation, marine, automotive & transportation systems; vehicles, aircraft, ships & vessels, as well as…
ADM239 – Two Process Input signal Arithmetic Unit Our ADM239 is a Din Rail Mounted Two Process Input signal Arithmetic Unit which is suitable for use as a Summator, Averager, Deviation, Differential or Subtractor in SIL 1, SIL... Our ADM239 is a Din Rail Mounted Two Process Input signal Arithmetic Unit which is suitable for use as a Summator, Averager, Deviation, Differential or Subtractor in SIL 1, SIL…
ADC314 – Three Process Input Adder/Averager Unit The ADC314 is our process input Adder and Averager unit from requested equation Any 3 Inputs are any process current or voltage drives that can be terminated in a PI... The ADC314 is our process input Adder and Averager unit from requested equation Any 3 Inputs are any process current or voltage drives that can be terminated in a PI…
ADC374 – Ramp Output Generator Unit The ADC374 is our ramp generator unit controlable via volt free contact closure inputs suitable for SIL 1, 2 & 3 applications Inputs are a free contact closure/opening to either... The ADC374 is our ramp generator unit controlable via volt free contact closure inputs suitable for SIL 1, 2 & 3 applications Inputs are a free contact closure/opening to either…
ADC375 – Ramp Output Generator Unit The ADC375 is our ramp generator with controlable timings via two input terminals unit for SIL 1, 2 & 3 applications Inputs are volt free contact closure/opening to either raise... The ADC375 is our ramp generator with controlable timings via two input terminals unit for SIL 1, 2 & 3 applications Inputs are volt free contact closure/opening to either raise…
ADC314X-4 – Four Input Averager/Summator unit with Dual Trip set points The ADC314X-4 is our four input summator unit with dual additional trip set points configurable upon request suitable for SIL 1, 2 & 3 applications Input can be any DC... The ADC314X-4 is our four input summator unit with dual additional trip set points configurable upon request suitable for SIL 1, 2 & 3 applications Input can be any DC…
AGS1126 – Heading Rate of Change Sensor ...monitoring applications, as 1oo1 architecture (HFT:0) This unit is suitable for areas such as aviation, marine, automotive & transportation systems; vehicles, aircraft, ships & vessels, as well as any other... …monitoring applications, as 1oo1 architecture (HFT:0) This unit is suitable for areas such as aviation, marine, automotive & transportation systems; vehicles, aircraft, ships & vessels, as well as any other…
ADC319 – Sample & Hold Transmitter / Isolator ...or voltage Function; The unit can be specified to switch from Sample to Hold mode on either a Contact Open or Close action. The unit is based on digital electronics... …or voltage Function; The unit can be specified to switch from Sample to Hold mode on either a Contact Open or Close action. The unit is based on digital electronics…
AGS1125X-2-EP – Dual Channel Inclinometer ...61508-2) safety instrumented system (SIS) loop monitoring applications, as 1oo1 architecture (HFT:0) This unit is suitable for construction, machinery, transportation and convertor systems, platforms, cranes & lifting equipment, vehicles, aircraft... …61508-2) safety instrumented system (SIS) loop monitoring applications, as 1oo1 architecture (HFT:0) This unit is suitable for construction, machinery, transportation and convertor systems, platforms, cranes & lifting equipment, vehicles, aircraft…
AGS1125-2 – Dual Channel Output Inclinometer ...safety instrumented system (SIS) loop monitoring applications, as 1oo1 architecture (HFT:0) This unit is suitable for construction, mining, agricultural machinery, transportation and converyor systems, ships, operation and automation technology as... …safety instrumented system (SIS) loop monitoring applications, as 1oo1 architecture (HFT:0) This unit is suitable for construction, mining, agricultural machinery, transportation and converyor systems, ships, operation and automation technology as…