ADC314X-4 – Four Input Averager/Summator unit with Dual Trip set points ...Current/Voltage that can be specified within the range on the datasheet given Output representing the total Sum of 4 x input signals, equally weighted or with internal scaling if required.... …Current/Voltage that can be specified within the range on the datasheet given Output representing the total Sum of 4 x input signals, equally weighted or with internal scaling if required….
ADC355X-2 – Pulse Input Repeater / Isolator / Splitter ...pulses from 5V to 200V, Current from 100uA Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C Relative Humidity: 5% to 95% RH... …pulses from 5V to 200V, Current from 100uA Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C Relative Humidity: 5% to 95% RH…
ADC355X-3 – Three Way Output Pulse Input Repeater / Splitter ...pulses from 5V to 200V, Current from 100uA Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C Relative Humidity: 5% to 95% RH... …pulses from 5V to 200V, Current from 100uA Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C Relative Humidity: 5% to 95% RH…
ADC355X-4 – Four Way Output Pulse Input Repeater / Splitter ...200V, Current from 100uA Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C Relative Humidity: 5% to 95% RH Performance 1000V RMS*. Input/Output(s)/Supply... …200V, Current from 100uA Environmental Condition Performance Mounting/Dimensions Environmental Condition Storage Temperature: -40°C to +70°C Operating Ambient: -15°C to +55°C Relative Humidity: 5% to 95% RH Performance 1000V RMS*. Input/Output(s)/Supply…
AMT250 AC V/I Input Transmitter The AMT250 is our alternating current and voltage signal transmitter suitable for SIL 1, 2 & 3 applications Input Single Output Double Output Transmitter Single Trip Transmitter Double Trip Double... The AMT250 is our alternating current and voltage signal transmitter suitable for SIL 1, 2 & 3 applications Input Single Output Double Output Transmitter Single Trip Transmitter Double Trip Double…
ADM230MPX – Surface Mounting Pressure Input Transmitter / Isolator ...up to 0-1500 bar. Output is any standard process current or voltage signal Environmental Condition Performance Mounting / Dimensions Environmental Condition Storing temperature: -40°C to +70°C Operating Ambient: -15°C to... …up to 0-1500 bar. Output is any standard process current or voltage signal Environmental Condition Performance Mounting / Dimensions Environmental Condition Storing temperature: -40°C to +70°C Operating Ambient: -15°C to…
ADM281 – Frequency Input Transmitter – Dual Output ...be any of sine, square or sawtooth waveforms with a min of 25Hz and Maximum 10KHz Output of standard process current or voltage. Isolation of 1KV RMS Environmental Condition Performance... …be any of sine, square or sawtooth waveforms with a min of 25Hz and Maximum 10KHz Output of standard process current or voltage. Isolation of 1KV RMS Environmental Condition Performance…
ADM282 – Pulse/Frequency Input Signal Trip Transmitter ...50mV and 200V p-p. Output is any standard process current or voltage signal Isolation of 1000V RMS Input/Output/Contacts/Supply/Earth Environmental Condition Performance Mounting / Dimensions Environmental Condition Storing temperature: -40°C to... …50mV and 200V p-p. Output is any standard process current or voltage signal Isolation of 1000V RMS Input/Output/Contacts/Supply/Earth Environmental Condition Performance Mounting / Dimensions Environmental Condition Storing temperature: -40°C to…
ADM286 – Frequency Input Trip Transmitter / Isolator ...is any regular pulse or repetitive waveform including Namur, Sine, Square or Sawtooth Output is any standard process current or voltage Environmental Condition Mounting / Dimensions Environmental Condition Storing temperature:... …is any regular pulse or repetitive waveform including Namur, Sine, Square or Sawtooth Output is any standard process current or voltage Environmental Condition Mounting / Dimensions Environmental Condition Storing temperature:…
ATA151KXL Overspeed Input Trip Amplifier The ATA151KXL is our overspeed trip amplifier suitable for SIL 1, 2 & 3 applications. Supply voltage 115VAC ±20% 230VAC ±20% 24VDC ±2.5V Input Bipolar DC current / voltage can... The ATA151KXL is our overspeed trip amplifier suitable for SIL 1, 2 & 3 applications. Supply voltage 115VAC ±20% 230VAC ±20% 24VDC ±2.5V Input Bipolar DC current / voltage can…