The AEC211 is our Thermocouple Temperature Signal Dual Output transmitter for SIL 1, 2 & 3 applications.
- Input is any type K, J or T Thermocouple Range with a minimum span of 5mV
- The standard output signal is 4-20mA, other ranges are available on request
Environmental Condition
Performance
Mounting/Dimensions
Environmental Condition
Storage Temperature: -20°C to +70°C
Operating Ambient: 0°C to +55°C
Relative Humidity: 5% to 95% RH
Performance
Isolation: 1000V RMS Input/Output/Supply
Mounting/Dimensions
Enclosure: 22.5w x 75h x 105d mm
Mounting: Din Rail (TS35)